Anaesthesia System KAM-B100

Anaesthesia System KAM-B100 is fully featured high-end general anaesthesia workstation equipped with wide screen display for respiratory trends, and other vital parameters. PCV and SIMV + PS modes ensure flexible ventilation. Comprehensive monitoring and intelligent gas flush and cut-off system for critical events improves patient safety.

Specifications
Ventilation Modes IPPV, PCV, SIMV + PS, PS and Manual
Tidal Volume 20 ml to 1500 ml
Pressure (Inspiratory) 5 cmH<sub>2</sub>O – 70 cmH<sub>2</sub>O
Pressure (Support) 3 cmH<sub>2</sub>O – 50 cmH<sub>2</sub>O
Electronic PEEP Off / 3 cmH<sub>2</sub>O – 30 cmH<sub>2</sub>O
I: E Ratio 4:1 to 1:8
Display 10.4” TFT Colour
Drive Pneumatically driven and electronically controlled
Pressure Trend P<sub>aw</sub>, P<sub>peak</sub>, P<sub>plat</sub>, P<sub>mean</sub>, PEEP
Volume Monitoring MV, VT, Freq
Graph Display P-T, F-T, P-V, F-V
Ventilation Gas (Optional CO<sub>2</sub>, AG, MAC) FiO<sub>2</sub>
Operational modes Closed, Semi-closed, Semi-open
Gas Supply O<sub>2</sub> , Air, N<sub>2</sub>O
Ventilator Pressure at Inlet 280 kPa ~ 600 kPa
Flowmeter O<sub>2</sub> : 0 ~ 10L/min <br> Air : 0 ~ 12L/min <br> N<sub>2</sub>O : 0 ~ 10L/min <br> Auxiliary O<sub>2</sub> : 0 ~ 12L/min
Vaporizer Supports 2 vaporizers
CO<sub>2</sub> Absorption Tank 3 L Autoclavable
Vaporizer Filling methods Pour Fill <br> Key Fill <br> Quick-Fil
Anaesthetic Agents Halothane, Enflurane, Isoflurane, Sevoflurane
APL Range Spontaneous breathing (SP) -70 cmH<sub>2</sub>O
T-slope 0 ~ 2s
Plateau (Inspiratory) Off / 5% – 60% Ti
Trigger Sensitivity 1 – 15 L/min
Alarm High/Low Airway Pressure, Sustained Airway Pressure, High/Low Minute Volume, High/Low FiO<sub>2</sub>, High Breath Rate, O<sub>2</sub> supply failure, Power failure, Apnea alarm, Mute : 110s
Power Supply 100 V ~ 240 V 50/60 Hz
Battery 24 V 4Ah ; 120 min
Dimensions 760 × 1300 × 630mm
Weight 100 Kgs
Features
  • Integrated 10.4” Monitor screen
  • Ventilation modes: IPPV, PCV, SIMV + PS, PS and Manual
  • CO2 Absorption: 3 Litre Autoclavable Tank
  • Flowmeter: minimum 25% O2/N2O mixture concentration
  • Double Vaporizer with Selectatec interlock
  • Comprehensive safety alarms with mute
  • Suitable for central or non-central OT
  • Suitable for Adult, Pediatric and Infant
  • Monitoring of O2, CO2 and anaesthetics (optional)
  • Heated Breathing system (optional)
Application

Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.