Intensive-Care Ventilator KIV-A200

Description

Intensive-Care Ventilator KIV-A100 is a high performance, closed-loop controlled, pneumatically-driven critical care ventilator with multiple ventilation modes. System features high resolution detachable touch screen with navigation knob to view monitored parameters, pulmonary mechanics waveform, lung volumes, flow-volume loops and three-level audio-visual alarm system with 360-degree panoramic alert light.

Features

  • Pneumatic-driven Flow
  • Multiple Ventilation modes with BIVENT and PRVC Modes
  • Invasive and Non-invasive Modes
  • Flexible Configuration
  • 15 Display Parameters
  • Alarm Recording Feature
  • Lung mechanics function monitoring


Specifications
Tidal Volume 20 ml ─ 2500 ml
Configurations Trolley or Ceiling Pendant
Respiratory Rate 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV) </br> 4 bpm ─ 100 bpm ( VCV/PCV/PRVC)
Psupport 0 kPa ─ 6 kPa
Pcontrol 0.5 kPa ─ 6 kPa
Pulmonary Mechanics Waveform 3
Loops 2
Standard Ventilation Modes VCV (A/C) </br> PCV (A/C) </br> SIMV (VCV) </br> SIMV(PCV) </br> SIMV (PRVC) </br> SPONT/CPAP </br> NIV/CPAP </br> NIV/PCV </br> BIVENT
Combined Ventilation Modes SPONT+PS </br> SIMV(VCV)+ PS </br> SIMV(PCV)+PS </br> SIMS(PRVC)+PS </br> BIVENT+PS </br> VCV+SIGH </br> NIV/CPAP+PS
Inspiration Time 0.1 s ─ 12 s
Inspiratory Pause Time 0 s ─ 4 s
FiO2 Range 21% ─ 100%
Trigger Sensitivity Pressure : - 2 kPa to 0 kPa (above PEEP) </br> Flow : 0.5 LPM ─ 20 LPM (base flow)
PEEP 0 kPa ─ 5 kPa
Suction < 2 min
Nebulizer 30 mins
Pressure Values P<sub>plat</sub> / P<sub>peak</sub> / P<sub>mean</sub> / PEEP
Volume / Flow values VTI / VTE / MV / MV<sub>spont</sub>
Time Values F<sub>total</sub> / F<sub>spont</sub> / I : E
Oxygen Monitoring Without O<sub>2</sub> sensor ( O<sub>2</sub> sensor optional )
Gas Supply O<sub>2</sub>, Air (0.28 MPa – 6 MPa)
Real-time Curves Pressure-Time </br> Flow-Time </br> Volume-Time </br> Pressure-Volume loop </br> Flow-Volume loop
Alarm Upper and Lower limits : MV, Paw, PEEP, Airway Pressure continuous high, VTE, Fspont high </br> Other Conditions : Tapnea, ,Power Fail, Nebulizer, Battery low, Battery exhausted, Air supply failure, O<sub>2</sub> supply failure, Air and O<sub>2</sub> supply failure, Fan block, Pipe block, Circuit disconnected
Display 12.1” TFT LCD touch screen
Internal Battery > 1 hour
Maximum Security Pressure ≤ 8 kPa
Compliance ≤ 4 ml / 100 Pa
Noise ≤ 65 dB (A)
Communication RS232, VGA, Nurse Call
Operational Temperature 5 °C to 40 °C
Relative Humidity ≤ 90 % (non-condensing)
Atmospheric Pressure 50 kPa – 106 kPa
Power Supply 110 V – 240 V (50 Hz / 60 Hz), 65 VA
Dimensions 328 x 410 x 410 mm
Weight 20 Kgs
Applications

Used in operating rooms, surgical care wards, intensive care unit, and other departments for pulmonary life-support during acute lung injury or respiratory distress which result in inadequate oxygenation or ventilation inability to protect the airway fluids.